The Core Facility comprises 12 climate chambers of various sizes and features, three workrooms, and a changing room. In addition to high-light chambers with height-adjustable tables, experimenters also have access to rack chambers for conducting their experiments. All chambers feature floor-level access to facilitate barrier-free loading.

Safety levels

Climate chambers 1 to 10, along with the adjacent corridors and two workrooms, are approved for genetic engineering work at safety level 1. Climate chambers 11 and 12, as well as the adjacent workroom, meet the requirements for genetic engineering work at safety level 2. These areas are separated from the S1 area of the facility by an additional door.

Climate chamber types in the S1 area

Core facility Klimakammer - Hochlichtkammern 1 bis 6
© Volker Lannert | Uni Bonn

High-light chambers
(Chambers 1 to 6)

  • Dimensions: 3,15 m x 4 m
  • Interior height: 2,4 m
  • Temperature range: 15-40 °C
  • Air humidity: 40-90%
  • Intensity of light: up to 1200 µmol/m2s
  • Light: LED modules with 5 channels
  • Water connections: City water and DI water
  • 4 height-adjustable tables (1,65 m x 0,91 m)
Core facility Klimakammer - Hochlichtkammern 7 und 8
© Volker Lannert | Uni Bonn

High-light chambers
(Chambers 7 and 8)

  • Dimensions: 3,1 m x 4 m
  • Interior height: 3,1 m
  • Temperature range: 10-40 °C
  • Air humidity: 60-90%
  • Intensity of light: up to 1200 µmol/m2s
  • Light: LED modules with 5 channels
  • Additional UV-B Channel (2 W/m2)
  • Water connections: City water and DI water
  • 4 height-adjustable tables (1,65 m x 0,91 m)
Core facility Klimakammer - Regalkammern 9  und 10
© Volker Lannert | Uni Bonn

Rack chambers
(Chambers 9 and 10)

  • Dimensions: 3 m x 3,5 m
  • Interior height: 2,4 m
  • Temperature range: 10-40 °C
  • Air humidity: 40-90%
  • Intensity of light: up to 300 µmol/m2s
  • Light: LED modules with 5 channels
  • Additional UV-B Channel (2 W/m2)
  • Water connections: City water and DI water
  • 2 Racks with 3 shelves (2,8 m x 0,8 m)

Climate chamber types in the S2 area

Eine Wissenschaftlerin und ein Wissenschaftler arbeiten hinter einer Glasfassade und mischen Chemikalien mit Großgeräten.
© Alina Klaus

Rack chamber
(Chamber 11)

  • Dimensions: 3 m x 3,5 m
  • Interior height: 2,4 m
  • Temperature range: 10-40 °C
  • Air humidity: 40-90%
  • Intensity of light: up to 300 µmol/m2s
  • Light: LED modules with 5 channels
  • Additional UV-B Channel (10 W/m2)
  • Water connections: City water and DI water
  • 2 Racks with 3 shelves (2,8 m x 0,8 m)
Eine Wissenschaftlerin und ein Wissenschaftler arbeiten hinter einer Glasfassade und mischen Chemikalien mit Großgeräten.
© Alina Klaus

High-light chamber
(Chamber 12)

  • Dimensions: 3 m x 3,5 m
  • Interior height: 2,4 m
  • Temperature range: 10-40 °C
  • Air humidity: 40-90%
  • Intensity of light: up to 1300 µmol/m2s
  • Light: LED modules with 5 channels
  • Additional UV-B channel (10 W/m2)
  • Water connections: City water and DI water
  • 4 height-adjustable tables (1,4 m x 0,91 m)

Technical equipment

The lighting system consists of LED modules that can be continuously adjusted across five channels, allowing users to customize the light spectrum to suit their experimental needs. Green working light enables work in the dark without impacting plant growth. In addition to day/night programs, day cycles with varying spectra, temperatures, and humidity settings can be programmed.

The available channels are:

Warm white (3000 K)
Cold white (6500 K)
Blue (444-457 nm)
Red (646-666 nm)
Deep red (710-740 nm)
UV-B (310 nm) (only in chambers 7 to 12)

Eine Wissenschaftlerin und ein Wissenschaftler arbeiten hinter einer Glasfassade und mischen Chemikalien mit Großgeräten.
© Alina Klaus
Core facility Klimakammer - Technische Ausstattung
© Volker Lannert | Uni Bonn
Eine Wissenschaftlerin und ein Wissenschaftler arbeiten hinter einer Glasfassade und mischen Chemikalien mit Großgeräten.
© Alina Klaus
Wird geladen